Xlpe insulated, lszh sheathed cable, 600v, iec605021 frtxah cu xlpe lszh awa lszh single core xlpe insulated, lszh bedded, aluminium wire armoured, lszh sheathed cable, 600v, bs6724. Low dielectric constant, a stable dielectric constant over all frequencies, and very high insulation resistance. Technical specification for xlpe insulated underground. As the most common type of insulation, all data provided in this handbook is based on cables with. Water tree retardant xlpe wtr xlpe as noted earlier, the phenomenon of water treeing can reduce the service life of xlpe cables. High voltage xlpe cable systems techincal user guide brugg cables page 5 the following rules apply for all organic insulation materials in general. It features flame retardant, low smoke and halogen free.
They are very prevalent in service aged xlpe and other solid dielectric cables, like pe and epr cables. In the 1970s, longterm dc voltage tests were performed in japan to see if the xlpe cable used for ac we have developed a crosslinked polyethylene dc xlpe insulating material. High voltage single core copper xlpe insulated armoured power cable. Table 1 shows the history of our dc xlpe cable development.
What is the difference between the xlpe and pvc insulated. Of cores nominal cross sectional area mm2 conductor type nominal thickness of insulation mm nominal thickness of sheath mm nominal overall diameter mm nominal weight kgkm a2n2xy116 1 16 rm 0. Prysmian manufactures comprehensive range of xlpe crosslinked polyethylene cables. Standards the cable is manufactured and tested according to bs 5467. Xlpe insulated, pvc sheathed cable, 600v, iec605021 xap cu xlpe pvc awa pvc single core xlpe insulated, pvc bedded, aluminium wire armoured, pvc sheathed cable, 600v, iec605021 xsp cu xlpe pvc swa pvc 2 cores 5 cores. Technical specification for 112233 kv nominal voltage ht xlpe power cables 1. The insulating material for ac xlpe cables, defined as acxlpe, exhibits.
Xlpeswapvc 4core bs 5467 600 v xlpe insulated steel wire armoured and pvc sheathed cable with copper conductors. What allows xlpe to endure these temperatures is that it is a thermoset material, while pvc is a thermoplastic. Position on cable run for one 5000 foot reel of 50,000 foot run 200 400 600 800 1200 1400 0 80 160 240 320 400 480 position on cable run sample number ac breakdown voltsmil. At present, numerous high voltage xlpe cable systems with nominal voltages up to 500 kv and. The process of crosslinking or vulcanisation consists of producing chemical bonds at intervals between the long molecular chains to give a ladder effect which prevents slippage between molecules. Electrical characteristics of xlpeinsulated medium voltage power cables, 6 30 kv effective resistance at 50 hz alternatingcurrent resistance copper conductor nominal voltage 610 kv 1220 kv 1830 kv crosssection approx ohmkm mm2 35 0,671 0,673 0,671 0,672 50 0,497 0,498 0,496 0,498 0,496 0,497. In terms of flexibility, polyethylene can be rated stiff to very hard, depending on molecular weight and density low density. Difference between the xlpe and pvc insulated cable. Crosslinking the polyethylene also enhances the chemical and oil resistance at elevated temperatures and makes it suitable for use as a low smoke zero halogen material. In each section, the cables are further categorized by its electrical component. Maximum short lasting less than 5 seconds temperature. A high voltage insulated cable circuit consists of three singlecore cables or one threecore cable with high voltage sealing ends at each end.
They can be used for almost all types of xlpe insulated cables with vastly different conductors, screens, sheaths, and armouring. Xlpe insulated power cable, lv power cable, xlpe lv power cable. Air is a poor insulator, having a nominal dielectric strength of only 55 volts per mil, while most cable insulations have dielectric strengths over 700 voltsmil. Low voltage cables are used to supply power to large motors and other industrial equipments. Prysmian has a full suite of xlpe cables, including single cores and multicores in both class 2 and flexible class 5, for entire construction market. The benefits of xlpe insulated cables eland cables. This page will help you to understand what is the difference between the xlpe and pvc insulated cables.
Xlpe marine grade wire is designed according to iec 60092353 standard with rating voltage up to 0. Electrical characteristics of xlpeinsulated medium. Type acic armoured control and instrumentation cable csa c22. The cost of energy losses can be reduced by using larger conductor. Low voltage cables ducab cable manufacturing company. Iec 60229 pdf free ebook download is the right place for every ebook files.
Teck 90 3c power 5000v ns tr xlpe t39 1609 view pdf. Pdf epr insulated cables for modern offshore systems. This is not th e same for xlpe insulated cables that have. When the length of the circuit exceeds the capacity of a cable reel, joints are. We have millions index of ebook files urls from around the world. As its name suggests, the insulation insulates the conductor when working at high voltage from the screen working at. This means that the molecules in xlpe are chemically bonded together and are more durable, contributing to the overall stability of the cable when faced. The design of xlpe cables conform to international standards and are similar to those in iec 60502 and iec 60840. When medium voltage mv xlpe insulated cables were first installed in the late 1960s, cable manufacturers and electric utilities expected them to perform. The development of high voltage xlpe cable systems goes back to the since then production and material technology have improved significantly, providing reliable and maintenancefree products to the utility industry. The xlpe insulation and the shields for conductor and insulation shall be extruded in one operation. Internal wiring xlpe insulated, ul 2460 cme wire and cable. Xlpe insulated halogenfree low smoke flameretardant lsoh power. Abb xlpe submarine cable systems 3 the xlpe cable should at least have a conductor cross section adequate to meet the system requirements for power transmission capacity.
Iec 60229 datasheet, cross reference, circuit and application notes in pdf format. Ii tests on power and control cables iii general information datasheets pvc insulated low voltage cables 70 c 7 yyfl, unarmoured 2, 3, 4 and 5cores 8 multicores 12 yyryfl, armoured 2, 3, 4 and 5cores 14 multicores 18 xlpe insulated low voltage cables 90 c 23 2xyfl, unarmoured, flame retardant 2, 3, 4 and 5cores 24 multicores 28. It can also be used for industrial installation such as in cable trench, cable duct, switchgear and in power stations. The polymeric forms of cable insulation are more susceptible to electrical discharge than impregnated paper and at the higher voltages, where the electrical stresses are high enough. This cable preferably used for supplying main power as a control cable. The semiconductive layer between conductor and insulation which compensates for air voids that exist between conductor and insulation. Xlpe is suitable for voltage ranges from low to extra high voltage, surpassing other insulation materials such as pvc, ethylene propylene rubber and silicone rubbers. Pvc insulated cable is 160 centigrade, xlpe insulated cable is 250 centigrade. Medium voltage underground cables 2 cable solutions to ensure the reliability of your energy network with energy as the basis of its development, nexans, the worldwide leader in the cable industry, offers an extensive range of cables and cabling systems. Single core and multicore cables with copper or aluminium conductor, xlpe insulated and pvc sheathed. Cables that are insulated with xlpe can run a higher current in the conductors.
Bs 5467 iec 605021 xlpe cable current rating scribd xlpe cable current rating download as word doc. These cables are to be used in underground residential distribution systems in queensland. Pvc insulated cable is 70 centigrade, xlpe insulated cable is 90 centigrade. Also known as crosslinked polyethylene, xlpe is a very good insulation in terms of electrical properties. These sealing ends are also called terminations or terminals.
Cme wire and cable 495 horizon drive ne, suite 100, suwanee, georgia 30024. These tree shaped moisture channels, in the presence of an. Cable types 1 armouredunarmoured xlpe insulated cables 2 lead sheathed cables 3 copper or aluminium pe tape with drain wire shielded cable sizes single core up to and including mm2 2 core up to and including 300 mm2 3 core up to and 2including 400 mm 4 core up to and including 500 mm2 5 core up to and 2including 95 mm specification. Amps aluminums conductor copper conductor aluminums copper ground duct. Xlpe insulated cable for medium and high voltages have, in general, circular conductors and only single core construction is adopted for the latter. Iec 60502 part 1pvc xlpe insulated cables single core multicore. Xlpe submarine cable systems attachment to xlpe land. Load losses in xlpe cables are primarily due to the ohmic losses in the conductor and the metallic screen. Fourcore, xlpe insulated, low voltage distribution cables.
Power cable catalogue aai, a powerflo technologies company. These cables are manufactured for a voltage range of 1kv to 3. Products xlpe cable,pvc cable,power cable,insulated. Xlpe insulated cables tenaga cable industries xlpe insulated cables low voltage xlpe cables. Current ratings the current ratings are thoroughly presented in era 6930 part v. Pdf 636kv medium voltage underground power cables xlpe. High voltage xlpe cable systems technical user guide.